Specifications table

SubjectEnvironmental Engineering, Artificial Intelligence
Specific Subject AreaEnergy consumption and CO2 emission of buildings, energy efficiency activities, building data, project costs and grants data
Type of DataData in comma seperated values format (.csv)
Python (.py) scripts used for preprocessing
Data formatPre-processed/pseudo-anonymized data in pivot tables
Data collectionRETROFIT-LAT comprises information on projects that received co-financing for renovations. Prior to renovation, details on energy consumption, building characteristics, and investment costs were provided by project applicants. Post-renovation data was gathered directly from building stakeholders. Data were collected from all completed projects under the LEIF-managed call “Reducing Greenhouse Gas Emissions from Households – Support for the Use of Renewable Energy Sources,” with contributions from several towns and buildings across the country. All buildings receiving financial support were included, with no sampling or selective inclusion process applied.
Data Source LocationAll relevant data can be found at RETROFIT-LAT's official Github Repositoy: https://github.com/epu-ntua/RETROFIT-LAT1
Related Research ArticleA. M. Tzortzis et al., “AI4EF: Artificial Intelligence for Energy Efficiency in the building sector,” SoftwareX, vol. 30, p. 102172, May 2025, doi: 10.1016/J.SOFTX.2025.102172.2.

Value of the data

Objective

Data description

RETROFIT-LAT is organized into two distinct datasets, each offering unique insights. The first dataset, titled EF comp, provides detailed information on building energy efficiency projects, including metadata said buildings (e.g. location, area, volume, and structural features), pre- and post-retrofit energy consumption, carbon dioxide emissions, and technical details of implemented energy-saving measures, The second dataset, named Sol pan comp focuses on solar panel installations, capturing data on financial support, electricity consumption from the grid, inverter specifications, solar electricity production, primary energy consumption changes, and CO2 emissions reductions.

EF comp dataset overview

The features in RETROFIT-LAT have been organized into distinct categories that provide a comprehensive overview of each building’s energy performance and efficiency measures. These categories include (a) General Building Information, (b) Energy Performance, (c) Energy Resource (d) CO2 Emission and Primary Energy Factors, (e) Energy Saving and Efficiency and (f) Energy Efficiency Measures. Each of these categories provides essential data for evaluating the energy performance and environmental impact of buildings before and after interventions.

General building information

In Table 1, we display the group of features that offer general details about each building, including its geographic location (region, town/village) and the year it began operation. These features provide essential context for understanding each building’s baseline attributes and forms the basis for analysing and reporting on implemented projects.

Table 1. General Building Information.

FeatureDescriptionData type
The DateDate when the project application was
submitted and its implementation started.
Text
RegionPlanning region where the house is located.Text
The Town/VillageTown or village where the house is located.Text
County/CityCounty or city where the house is located.Text
Initial year of exploitationInitial year of exploitation of the buildingInteger/Year

This table details the fundamental characteristics of each building in the dataset, focusing on geographic location (including planning region, town/village) and the year the building first began operation. This information provides essential context for understanding the baseline attributes of the buildings before any retrofitting projects.

The dataset covers five planning regions in Latvia: Riga, Zemgale, Kurzeme, Vidzeme and Latgale, with the distribution of buildings across them shown in Figure 1.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure1.gif

Figure 1. Distribution of data across Latvian regions.

Illustrates the geographical spread of the 1010 residential building projects within the five planning regions of Latvia: Riga, Zemgale, Kurzeme, Vidzeme, and Latgale.

Location is also indicated by the columns. The town/village and County/City, which exhibit a high number of distinct values with 122 and 68 unique entries respectively.

Building characteristics

The dataset also encompasses detailed information about the structure of the buildings, offering valuable insights into their impact on energy efficiency and potential for optimization. Table 2 presents the features regarding a building’s physical attributes, thermal performance, and operational parameters. It includes metrics such as Building Total Area, Room Volume, and Reference Area, which are fundamental for energy performance calculations.

Table 2. Building Characteristics.

FeatureDescriptionUnit (measure)
Building Total
Area
The total area of the building.m2
Room VolumeThe total volume of rooms in the building.m3
Average Floor
Height
The average height of each floor.m
Reference AreaThe reference area used in energy performance calculations.m2
Above-Ground
Floors
The number of floors above ground level in the building.Floor number
Underground FloorIndicates whether the building has underground floors.Yes/No
MansardIndicates if the building has a mansard roof.Yes/No
Roof FloorIndicates if the building has a roof floor.Yes/No
Area of the External SurfaceThe total area of the external surface of the building.m2
Average Heat
Transfer Coefficient
The average heat transfer coefficient, which indicates the
insulation performance.
W/(m2K)
Average Heat
Transfer
Coefficient1
An alternative value of the heat transfer coefficient for
different parts of the building.
W/(m2K)
Building
Calculated Heat
Loss Coefficient
The calculated value for the heat loss coefficient of the
building.
W/(m2K)
Building Allowable
Heat Loss
Coefficient
The allowable value for the building’s heat loss coefficient
based on regulations.
W/(m2K)
Indoor
Temperature
Heating
The indoor temperature set for heating.°C
Indoor
Temperature for Cooling
The indoor temperature set for cooling.°C
Air Exchange RateThe rate at which air is exchanged in the building.h−1
Ventilation Heat
Loss Coefficient
The coefficient that quantifies the heat loss due to ventilation.W/(m2K)

This table presents a comprehensive overview of the physical attributes, thermal performance metrics, and operational parameters of the buildings in the study. Key features include building size (total area, room volume, reference area), structural details (average floor height, number of above-ground/underground floors, presence of a mansard or roof floor, external surface area), thermal insulation properties (average heat transfer coefficients, calculated and allowable heat loss coefficients), and operational settings (indoor temperatures for heating and cooling, air exchange rate, ventilation heat loss coefficient).

Structural details related to the buildings’ flooring (e.g average floor height, the number of above-ground/underground floors) provide important insights into the building’s design. As a general overview, 66% of the buildings have two above-ground floors. While only 7 buildings include three floors. The remaining buildings consist of a single floor and an underground floor is present in 42% of the properties. A roof floor exists in approximately 14% of the houses and 24% are constructed with a mansard roof, indicating varied architectural designs that contribute to the dataset’s diversity.

Thermal performance is evaluated through metrics (e.g average heat transfer/loss coefficients etc), which reflect the building’s insulation and compliance with energy standards. Operational settings (e.g indoor temperatures for heating and cooling, Air Exchange Rate etc) are critical parameters for assessing energy consumption and ensuring thermal comfort.

Energy performance

Energy performance features, such as Energy Class (Initial Energy Class, Energy Class After), which reflect the building’s energy efficiency before and after improvements, are illustrated in Table 3. In Figure 2, we present the distribution of buildings’ energy classes before and after renovations, highlighting the impact of these interventions on energy efficiency. Initially most buildings belonged to classes D, E, and F. After the retrofitting, all buildings were upgraded to classes A (10%), B (22%), C (68%).

Table 3. Energy Performance.

FeatureDescriptionUnit (Measure)
Energy Consumption
Before
The total energy consumption of the
building before energy-saving interventions.
kWh/m2
Initial Energy ClassThe energy class of the building beforeEnergy Class (e.g. A,B,C)
Heat Energy
Consumption
Before
The total heat energy consumption of the
building before the renovation.
kWh/m2
Carbon Dioxide Emissions
Before
The carbon dioxide emissions from the building’s
energy consumption before renovation.
kg CO2/m2 per
year
Energy Consumption AfterThe total energy consumption of the
building after energy-saving interventions.
kWh/m2
Energy Class AfterThe energy class of the building afterEnergy Class (e.g. A,B,C)
Heat Energy Consumption
After
The total heat energy consumption of the
building after renovation.
kWh/m2
Consumption for
Hot Water After
The energy consumption for hot water after
energy-saving interventions.
kWh/m2
Consumption for Mechanical
Ventilation After
The energy consumption for mechanical
ventilation after interventions.
kWh/m2
Consumption for
Lighting After
The energy consumption for lighting after
renovation.
kWh/m2
Consumption for
Cooling After
The energy consumption for cooling after
renovation.
kWh/m2
Primary
Non-Renewable
Energy
The amount of non-renewable energy used after
renovation.
kWh/m2
Primary Total Energy
Consumption
The total amount of energy consumed after
renovations, considering all sources.
kWh/m2
Almost Zero Energy BuildingIndicates if the building meets almost zero
energy standards after renovation.
Yes/No
Carbon Dioxide
Emission
Tons After
The total carbon dioxide emissions after energy-
saving interventions.
tons CO2 per year
Carbon Dioxide
Emission After
The carbon dioxide emissions after renovations.kg CO2/m2 per
year

This table outlines the energy consumption and environmental impact of the buildings, both before and after the implementation of energy-saving interventions. It includes the initial and final energy classes, total and heat energy consumption, consumption for specific uses after renovation (hot water, mechanical ventilation, lighting, cooling), primary energy consumption (non-renewable and total), and carbon dioxide emissions. It also indicates whether a building meets almost zero energy building standards after renovation.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure2.gif

Figure 2. Initial energy class and Energy class after distributions.

Showcases the shift in the energy efficiency of the buildings before and after retrofitting interventions.

Specifically, the heatmap in Figure 3 illustrates the transitions between initial and final energy classes in detail, highlighting the specific patterns of energy class progression within the dataset.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure3.gif

Figure 3. Heatmap of Initial energy class and Energy class after combinations.

A detailed view of the transitions between the initial and final energy classes for the retrofitted buildings, illustrating the specific patterns of energy class progression within the dataset.

The Energy Consumption (e.g., Energy Consumption Before, Energy Consumption After) measures the total energy used by the building. Figure 4a illustrates the distribution of total energy consumption both before and after the implementation of energy efficiency measures, capturing a significant reduction in their values. As shown in Figure 4b, a similar pattern is observed in the case of energy consumption for heating, which accounts for the largest share of total energy demand.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure4.gif

Figure 4. Total and heat energy consumptions before and after the renovation.

Visualizes (a) the distribution of total energy consumption before and after the implementation of energy efficiency measures (b) a similar pattern for heat energy consumption, which represents the largest share of total energy demand.

This group of features also includes specific categories regarding energy consumption (e.g. consumption for mechanical ventilation/lighting/cooling) highlighting the changes resulting from energy-saving interventions in each system. The Primary Energy (e.g., Primary Non-Renewable Energy, Primary Total Energy Consumption) measures the primary energy usage from both renewable and non-renewable sources after renovation, with Primary Non-Renewable Energy focusing on non-renewable resources.

Carbon Dioxide Emissions (e.g. Carbon Dioxide Emissions Before, Carbon Dioxide Emissions After) track the amount of CO2 emissions associated with the building’s energy consumption before and after renovations. Figure 5 visualizes the corresponding distributions, emphasizing the environmental benefits of the retrofitting actions. Lastly, the Almost Zero Energy Building feature indicates whether the building meets almost zero energy standards after renovation.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure5.gif

Figure 5. KDE plot of Carbon dioxide emissions before and after the renovation.

Visualizes the distributions of CO2 emissions associated with the buildings' energy consumption.

Energy saving and efficiency

The Energy Saving and Efficiency category, illustrated in Table 4, focuses on the impact of energy-saving measures implemented in the building. It includes features such as Heat Saving for Heating, which measures the reduction in heat energy consumption for heating purposes after renovations. Total Energy Consumption Saving tracks the overall energy savings achieved across all systems and interventions, providing a comprehensive view of the building’s energy efficiency improvements. Additionally, Saving of Heat Energy specifically quantifies the amount of heat energy conserved through various energy-saving measures. These features collectively help assess the effectiveness of renovations in reducing energy usage, improving efficiency, and lowering operational costs.

Table 4. Energy Saving and Efficiency.

FeatureDescriptionUnit (Measure)
Heat Saving for
Heating
The amount of heat energy saved for
heating after interventions.
kWh/m2
Total Energy
Consumption
Saving
The total energy saved after
renovations.
kWh/m2
Saving of Heat
Energy
The total amount of heat energy saved
through energy-saving measures.
%

This table focuses specifically on the quantifiable impact of the energy efficiency measures implemented in the buildings. It presents metrics such as heat energy saved for heating, total energy consumption saving, and the percentage saving of heat energy achieved through the retrofitting actions.

Energy resource use

Features describing energy resource uses (e.g heating/hot water, ventilation etc) provide insight into the primary and secondary energy sources used to power key building systems. These features help in understanding the overall energy mix and efficiency of the building, capturing different resources utilized. Table 5 presents these features in detail, outlining the proportions of energy sources such as electricity, natural gas, or renewable options, offering a clear perspective on resource allocation. Note that in many buildings distinct energy resources are not allocated for specific systems such as ventilation. Similarly, the presence of a secondary energy resource for heating, hot water, or cooling is not applicable in certain cases and, therefore, the corresponding features are assigned the value ’-’. This data is crucial for evaluating sustainability and optimizing energy consumption across multiple buildings.

Table 5. Energy Resource Use.

FeatureDescriptionData type
Energy Resource for Heating 1The primary energy resource used for heating (e.g., gas,
electricity).
Text
Energy Resource for Heating 2The secondary energy resource used for heating.Text
Energy Resource for Hot Water 1The primary energy resource used for hot water.Text
Energy Resource for Hot Water 2The secondary energy resource used for hot water.Text
Energy Resource for VentilationThe primary energy resource used for the ventilation system.Text
Energy Resource for Cooling 1The primary energy resource used for cooling the building.Text
Energy Resource for Cooling 2The secondary energy resource used for cooling.Text

This table provides insights into the primary and secondary energy sources utilised to power key building systems, including heating, hot water, ventilation, and cooling. It lists the specific energy resources (e.g., gas, electricity, renewable options) used for each system. The use of '-' indicates instances where a distinct energy resource is not allocated for a specific system or where a secondary energy resource is not applicable.

CO2 emission and primary energy factors

Features regarding CO2 emission factors (e.g heating, hot water, ventilation etc.) indicate the amount of carbon dioxide emissions associated with the energy consumed by building energy systems. These factors, depicted in Table 6 are based on the specific energy sources used in each system, providing a measure of their environmental impact. Similarly, non-renewable/renewable energy factors for said energy systems capture the non-renewable/renewable energy consumed by these systems. The total factors are derived as the sum of the corresponding non-renewable and renewable factors. This data also assist in the evaluation of a building’s sustainability, supporting decisions towards reducing emissions and improving energy efficiency.

Table 6. CO2 Emission and Primary Energy Factors (X refers to HVAC systems: heating 1, heating 2, hot water 1, hot water 2, ventilation, cooling 1, cooling 2).

FeatureDescriptionData type
CO2 emission factor for XCO2 emission factor for X based on the energy source used.Integer
Non-renewable factor for XPrimary energy factor for the part of non-renewable energy resources for X.Integer
Renewable factor for XPrimary energy factor for the part of renewable energy resources for X.Integer
Total factor for XTotal primary energy factor for X based on the energy source used.Integer

This table details the carbon dioxide emission factors associated with the energy consumed by different HVAC (Heating, Ventilation, and Air Conditioning) systems, based on their specific energy sources. It also presents the non-renewable and renewable primary energy factors for these systems, as well as the total primary energy factor, offering a measure of the environmental impact and sustainability of each system.

Energy efficiency measures

Finally, we have retrofitting actions (e.g Carrying out Construction Works, Reconstruction of Engineering Systems etc) that represent different energy efficiency measures in building renovation and upgrades. These measures focus on improving the overall energy performance of the building. For instance, Carrying out Construction Works refers to the work done on enclosing structures, while Reconstruction of Engineering Systems involves upgrading systems like ventilation or recuperation to boost energy efficiency. The Water Heating System refers to the installation of a new system to improve hot water energy use, and Heat Installation focuses on ensuring that heating is produced using renewable energy sources. Table 7 illustrates these measures in detail, highlighting their significance as crucial steps in enhancing a building’s sustainability and energy efficiency.

Table 7. Energy efficiency measures.

FeatureDescriptionData type
Carrying out construction worksCarrying out construction works in the enclosing structuresBoolean
Reconstruction of engineering
systems
Reconstruction of engineering systems
(ventilation, recuperation) to increase the energy efficiency of the house
Boolean
Water heating systemInstallation of a new water heating systemBoolean
Heat installationInstallation of heat installations to ensure the production of heat from
renewable energy sources
Boolean

This table describes the various retrofitting actions undertaken to improve the energy efficiency of the buildings. These measures include carrying out construction works on enclosing structures, reconstruction of engineering systems (ventilation, recuperation), installation of new water heating systems, and installation of heat installations to utilize renewable energy sources for heating.

Figure 6 visualizes the number of buildings that implemented each energy efficiency measure compared to those that did not, providing an overview of the adoption rates for these retrofitting actions.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure6.gif

Figure 6. Clustered Bar Plot for Energy efficiency measures implementation.

Comparison between the number of buildings that implemented each of the energy efficiency measures (Carrying out Construction Works, Reconstruction of Engineering Systems, Water heating system, Heat installation) to those that did not, providing an overview of the adoption rates for these retrofitting actions.

Sol pan comp dataset overview

The dataset contains detailed information regarding solar panel projects, funded through public support in Latvia, that focus on energy efficiency and sustainability metrics. Key features include the region attribute which categorizes projects by Latvia’s five planning regions, enabling regional analysis. Quantitative data include pre- and post-project electricity consumption (MWh/year), and primary energy consumption (kW), allowing assessment of energy-saving actions. The dataset also records solar panel electricity production (MWh/year), alongside CO2 emissions reduction (t CO2 eq/year) as an environmental impact metric (Figure 7). Table 8 provides a detailed overview of these features, including their descriptions and units of measure. This comprehensive dataset is valuable for analysing the impact of solar energy projects on energy efficiency and greenhouse gas reduction.

556594ae-bab3-45c1-bc82-f1d1c6335ca8_figure7.gif

Figure 7. Solpancomp: Analysis of energy efficiency measures, including emissions reduction, data distribution, and energy consumption metrics.

This figure presents various analyses related to the solar panel installation dataset: (a) shows CO2 emissions reduction by region, (b) illustrates the data distribution by region for solar panel projects, and (c) displays the primary energy consumption before and after implementation of solar panel systems.

Table 8. Feature Descriptions for Solar Panel comp dataset.

FeatureDescriptionUnit (measure)
The dateThe year when the project application was submitted and its
implementation started.
Text
RegionThe planning regions where the house is located.Text
Electricity
consumption from the grid
Electricity consumption from the grid before the project.MWh/year
Primary energy consumption
before
Primary energy consumption before the installation of the solar
panel system during the project.
kW
Current inverter set powerCurrent inverter set power - inverter power that was already
installed before the project.
kW
Inverter set power in projectInverter set power in project - in addition to the existing inverter.kW
Electricity
produced by solar panels
The amount of electricity produced by the solar panels, which
are installed in the project.
MWh/year
Primary energy consumption
after
Primary energy consumption after installing the solar panel
system.
MWh/year
Reduction of primary energyReduction of primary energy.MWh/year
CO2 emissions reductionCO2 emissions reduction.tons CO2 eq/year

This table provides a detailed overview of the features included in the solar panel installation dataset. It describes attributes such as the project submission year, planning region, electricity consumption from the grid (before and after the project), primary energy consumption (before and after installation), current and project-related inverter power, electricity produced by solar panels, reduction of primary energy, and CO2 emissions reduction.

Experimental design, materials and methods

In the data preprocessing stage, several essential steps were undertaken to ensure data consistency across the dataset. Basic edits were applied to eliminate inconsistencies and harmonize formatting (e.g. different value representations, translation of entries remaining in Latvian etc.). Energy classes were validated and corrected to align with the Latvian energy efficiency system16. As regards the null values, the value ’-’ was retained to indicate the non-existence of an energy system (and energy factor respectively), while missing values were preserved to allow users to handle them as needed.

Limitations

RETROFIT-LAT exhibit some common limitations. Both of its datasets are of limited size, recording combined data from only 1010 buildings. Another key issue is data scarcity, where specific features such as Latvian region, energy class, and energy efficiency measures, are under-represented. This imbalance is illustrated more notably in Figure 1, Figure 2 and Figure 6 respectively.

Ethics statement

It is clearly stated that the work carried out for the needs of the data collection and presentation does not involve human subjects, animal experiments, or any data collected from social media platforms. It should be further clarified that no personal data are included in RETROFIT-LAT concerning the participant buildings’ stakeholders and that the platform(s)’ data redistribution policies are fully complied with it.

Data availability statement

Due to ethical and privacy considerations, the dataset cannot be fully shared in its original form. The study protocol and data handling procedures were reviewed by LEIF, which required that public data release be restricted.

To minimize privacy risks, only minimal modifications were made. Columns containing personally identifiable information (PII), including Project number, Granted support, Home address and Energy audit number were entirely removed. Location-related data in the The town/village and County/City columns was pseudo-anonymized by replacing unique values with sequential labels (e.g town1, town2, and county1 county2 respectively) Furthermore, the The date column was adjusted to display only the year, omitting specific day and month details. These steps are important to ensure compliance with data protection standards, homeowner’s individual privacy, and maintain the dataset’s utility for meaningful analysis.

Access to the full dataset may be granted upon request, subject to approval by LEIF, and with the signing of a data use agreement. Researchers interested in accessing the full dataset can contact the authors for more details.

A limited version of the dataset is publicly available under an open CC-BY 4.0 license at RETROFIT-LAT’s official Github repository1 and is assigned the Persistent Identifier (DOI): 10.5281/zenodo.14697230. This version excludes sensitive information and includes only the anonymized data, which still allows for meaningful analysis.

Zenodo: RETROFIT-LAT: A comprehensive dataset for energy efficiency investments in Latvia, DOI: https://doi.org/10.5281/zenodo.15316421 ()

The project contains a limited version of the dataset is publicly available.

1. epu-ntua/RETROFIT-LAT-1.1.2.zip

Data are available under the terms of the Creative Commons Attribution 4.0 International license (CC-BY 4.0). 

References

  • 1.  Tzortzis A, Rempi P: epu-ntua/RETROFIT-LAT. Zenodo. 2025. http://www.doi.org/10.5281/zenodo.14697230
  • 2.  Tzortzis AM, Kormpakis G, Pelekis S, et al.: AI4EF: Artificial Intelligence for Energy Efficiency in the building sector. 2024; Accessed: Apr. 29, 2025. Publisher Full Text
  • 3.  Sarmas E, Spiliotis E, Marinakis V, et al.: A meta-learning classification model for supporting decisions on energy efficiency investments. Energy Build. 2022; 258: 111836. Publisher Full Text
  • 4.  Palm J, Reindl K: Understanding energy efficiency in Swedish residential building renovation: a practice theory approach. Energy Res Soc Sci. 2016; 11: 247–255. Publisher Full Text
  • 5.  Karakolis E, Pelekis S, Mouzakitis S, et al.: Artificial Intelligence for next generation energy services across Europe-the I-Nergy project. 2022; Accessed: Apr. 29, 2025. Publisher Full Text
  • 6.  Kormpakis G, Kapsalis P, Alexakis K, et al.: An advanced visualisation engine with role-based access control for building energy visual analytics. 13th International Conference on Information, Intelligence, Systems and Applications, IISA. 2022. Publisher Full Text
  • 7.  Senarathne LR, Nanda G, Sundararajan R: Influence of building parameters on energy efficiency levels: a Bayesian network study. Adv Build Energy Res. 2022; 16(6): 780–805. Publisher Full Text
  • 8.  Du J, Yu C, Pan W: Multiple influencing factors analysis of household energy consumption in high-rise residential buildings: evidence from Hong Kong. Build Simul. 2020; 13(4): 753–769. Publisher Full Text
  • 9.  Tzortzis AM, Pelekis S, Spiliotis E, et al.: Transfer learning for day-ahead load forecasting: a case study on European national electricity demand time series. Mathematics. 2024; 12(1): 19. Publisher Full Text
  • 10.  Voumik LC, Islam MJ, Raihan A: Electricity production sources and CO2 emission in OECD countries: static and dynamic panel analysis. Glob Sustain Res. 2022; 1(2): 12–21. Publisher Full Text
  • 11.  Rempi P, Pelekis S, Tzortzis AM, et al.: Explainable AI for building energy retrofitting under data scarcity. 2025; Accessed: Apr. 29, 2025. Publisher Full Text
  • 12.  Michalakopoulos V, Pelekis S, Kormpakis G, et al.: Data-driven building energy efficiency prediction using physics-informed neural networks. 2024 IEEE Conference on Technologies for Sustainability, (SusTech). 2024; 84–91. Publisher Full Text
  • 13.  Pelekis S, Pountridis T, Kormpakis G, et al.: DeepTSF: codeless machine learning operations for time series forecasting. SoftwareX. 2024; 27: 101758. Publisher Full Text
  • 14.  He B, Zheng H, Zhang Q, et al.: Toward a comprehensive economic comparison framework for solar projects: a case study of utility and residential scales. Sustainability. 2024; 16(23): 10320. Publisher Full Text
  • 15.  Kishara KK, Obulinji HW, Ondimu KN: Analysis of the spatial variations in the adoption of solar energy technologies among households in rural and urban areas of Konoin sub-County, Kenya. Open Access Res J Sci Technol. 2024; 11(2): 99–105. Publisher Full Text
  • 16.  Ēku energoefektivitātes aprēķina metodes un ēku energosertifikācijas noteikumi. Accessed: Jul. 07, 2025. Reference Source