Abstract

Background

Polymethylmethacrylate (PMMA) bone cement is extensively used in spinal procedures such as vertebroplasty and kyphoplasty, while its use in percutaneous cement discoplasty (PCD) is not yet widely spread. A main issue for both application sites, vertebra and disc, is the mismatch in stiffness between cement and bone, potentially resulting in adjacent vertebral fractures and adjacent segment disease. Tailoring the cement modulus using additives is hence an interesting strategy. However, there is a lack of data on the tensile and tension-compression fatigue properties of these cements, relevant to the newly researched indication of PCD.

Method

A commercial PMMA cement (VS) was modified with 12%vol of linoleic acid (VSLA) and tested for quasi-static tensile properties. Additionally, tension-compression fatigue testing with amplitudes ranging from +/-5MPa to +/-7MPa and +/-9MPa was performed, and a Weibull three-parameter curve fit was used to calculate the fatigue parameters.

Results

Quasi-static testing revealed a significant reduction in VSLA’s Young’s Modulus (E=581.1±126.4MPa) compared to the original cement (E=1478.1±202.9MPa). Similarly, the ultimate tensile stress decreased from 36.6±1.5MPa to 11.6±0.8MPa. Thus, VSLA offers improved compatibility with trabecular bone properties. Fatigue testing of VSLA revealed that as the stress amplitude increased the Weibull mean number decreased from 3591 to 272 and 91 cycles, respectively. In contrast, the base VS cement reached run-out at the highest stress amplitude. However, the lowest stress amplitude used exceeds the pressures recorded in the disc in vivo, and VSLA displayed a similar fatigue life range to that of the annulus fibrosis tissue.

Conclusions

While the relevance of fully reversed tension-compression fatigue testing can be debated for predicting cement performance in certain spinal applications, the results of this study can serve as a benchmark for comparison of low-modulus cements for the spine. Further investigations are necessary to assess the clinical feasibility and effectiveness of these cements.

Corresponding author
Cecilia Persson
0000-0001-6663-6536
Grant information

This research has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 812765 as well as EIT Health (SOFTBONE, project nr 20519), supported by EIT, a body of the European Union.

The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

Copyright
© 2023 Salim Ghandour (Co-Author); Iain Christie (Co-Author); Caroline Öhman Mägi (Co-Author); Cecilia Persson (Corresponding Author, Co-Author) Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

First version published
Latest version published

Comments

Authors & roles

Salim Ghandour

Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden

Roles
Co-Author, Formal Analysis, Visualization, Writing – Original Draft Preparation, Writing – Review & Editing
0000-0002-7387-1224

Iain Christie

Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden

Division of Applied Materials Science, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden

Roles
Co-Author, Conceptualization, Data Curation, Formal Analysis, Investigation, Methodology, Software, Writing – Original Draft Preparation, Writing – Review & Editing

Caroline Öhman Mägi

Division of Applied Materials Science, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden

Roles
Co-Author, Conceptualization, Methodology, Project Administration, Resources, Supervision, Writing – Review & Editing
0000-0003-2709-9541

Cecilia Persson

Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Uppsala County, 75121, Sweden

Roles
Corresponding Author, Co-Author, Conceptualization, Funding Acquisition, Methodology, Project Administration, Resources, Supervision, Writing – Review & Editing
0000-0001-6663-6536

Downloads over the last 12 months:

Cited by

via Crossref

View citing articles